Facebook Instagram Twitter RSS Feed PodBean Back to top on side

Comparison of extensometric results measured in the Vyhne Tidal Station (Slovakia) and in the Sopronbánfalva Geodynamic Observatory (Hungary

In: Contributions to Geophysics and Geodesy, vol. 51, no. 4
Gyula Mentes Číslo ORCID - Ladislav Brimich Číslo ORCID - Martin Bednárik Číslo ORCID - Jozef Bódi Číslo ORCID
Detaily:
Rok, strany: 2021, 391 - 402
Jazyk: eng
Kľúčové slová:
extensometer, Earth tides, tectonic deformation, ocean tide loading, comparison of observatories
O článku:
Two extensometer stations have been set up at the margin of the Pannonian Basin to monitor tectonic movements as well as Earth tides and related phenomena. Because the Sopronbánfalva Geodynamic Observatory (SGO) in Hungary and the Vyhne Tidal Station (VTS) in Slovakia are located in different geological, topographic, and tectonic environments, the analysis and comparison of the extensometer data measured here provides a useful opportunity to interpret the observed data. The tectonic deformation at the SGO shows an average contraction of: −2.94 μstr y−1 (1 μstr is 10−6 relative deformation) which can be explained by the uplift of the Alps and the anticlockwise motion of the Adria microplate, causing compression in the Eastern Alps. At the VTS an average compression of −14.8 nstr y−1 (1 nstr is 10−9 relative deformation) was measured which can be explained by the NW compression direction in this area. The measured deformations in both observatories show a good agreement with the results of GPS measurements. The deformation at the VTS is characterized by small dilatation anomalies caused by the different topographic, tectonic environment and probably by the high heat flow in the area of the station. At this station the calculated amplitude factors for O1, P1, K1, M2 are 1.01482, 1.21691, 0.83173, 1.09392 and the ocean load corrected values are 1.10817, 1.35717, 0.92809, 1.28812, respectively. At the SGO the calculated amplitude factors for the same tidal components are 0.58776, 0.38967, 0.41548, 1.00564 and the ocean load corrected values are 0.98893, 1.89117, 1.00430, 1.04962, respectively. These results show that the effect of the ocean tide loading is greater at Sopronbánfalva, than at Vyhne. Based on the comparison, we can say that the result of the local strain measurement can be considered realistic.
Ako citovať:
ISO 690:
Mentes, G., Brimich, L., Bednárik, M., Bódi, J. 2021. Comparison of extensometric results measured in the Vyhne Tidal Station (Slovakia) and in the Sopronbánfalva Geodynamic Observatory (Hungary. In Contributions to Geophysics and Geodesy, vol. 51, no.4, pp. 391-402. 1338-0540. DOI: https://doi.org/10.31577/congeo.2021.51.4.5

APA:
Mentes, G., Brimich, L., Bednárik, M., Bódi, J. (2021). Comparison of extensometric results measured in the Vyhne Tidal Station (Slovakia) and in the Sopronbánfalva Geodynamic Observatory (Hungary. Contributions to Geophysics and Geodesy, 51(4), 391-402. 1338-0540. DOI: https://doi.org/10.31577/congeo.2021.51.4.5
O vydaní:
Vydavateľ: ESI SAS
Publikované: 22. 12. 2021
Verejná licencia:
CC BY-NC-ND